{"id":3938,"date":"2015-12-21T18:10:44","date_gmt":"2015-12-21T17:10:44","guid":{"rendered":"https:\/\/www.zensol.net\/?post_type=portfolio&#038;p=3938"},"modified":"2026-10-12T08:24:49","modified_gmt":"2026-10-12T07:24:49","slug":"res-24","status":"publish","type":"portfolio","link":"https:\/\/www.zensol.com\/fr\/product\/res-24\/","title":{"rendered":"MESURE DE LA R\u00c9SISTANCE AVANT INSERTION &#8211; RES24"},"content":{"rendered":"<div class='flex_column av-bwsomq-bc6c23a8a5f6ea97ce42258fd2133380 av_one_half  avia-builder-el-0  el_before_av_one_half  avia-builder-el-first  first flex_column_div '     ><style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-11ej9e-7c4326124738dbe688b54d14fd5667d4\">\n#top .avia-gallery.av-11ej9e-7c4326124738dbe688b54d14fd5667d4 .avia-gallery-thumb a{\nwidth:20%;\n}\n<\/style>\n<div  class='avia-gallery av-11ej9e-7c4326124738dbe688b54d14fd5667d4 avia_animate_when_visible  avia-builder-el-1  avia-builder-el-no-sibling  avia_lazyload avia-gallery-animate avia-gallery-1'  itemprop=\"image\" itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/ImageObject\" ><meta itemprop=\"contentURL\" content=\"https:\/\/www.zensol.com\/fr\/product\/res-24\/\"><a class='avia-gallery-big fakeLightbox lightbox avia-gallery-big-crop-thumb ' href=\"https:\/\/www.zensol.com\/wp-content\/uploads\/2015\/09\/RES.gif\"  data-onclick='1' title='RES' ><span class='avia-gallery-big-inner'  itemprop=\"thumbnailUrl\" ><img decoding=\"async\" class=\"wp-image-7599 avia-img-lazy-loading-not-7599\"  width=\"388\" height=\"295\" src=\"https:\/\/www.zensol.com\/wp-content\/uploads\/2015\/09\/RES.gif\" title='RES' alt='' \/><\/span><\/a><div class='avia-gallery-thumb'><a href=\"https:\/\/www.zensol.com\/wp-content\/uploads\/2015\/09\/RES.gif\" data-rel='gallery-1' data-prev-img='https:\/\/www.zensol.com\/wp-content\/uploads\/2015\/09\/RES.gif' class='first_thumb lightbox ' data-onclick='1' title='RES'  itemprop=\"thumbnailUrl\"  ><img decoding=\"async\" class=\"wp-image-7599 avia-img-lazy-loading-not-7599\"   src=\"https:\/\/www.zensol.com\/wp-content\/uploads\/2015\/09\/RES.gif\" width=\"388\" height=\"295\"  title='RES' alt='' \/><div class='big-prev-fake'><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-7599 avia-img-lazy-loading-7599\"  width=\"388\" height=\"295\" src=\"https:\/\/www.zensol.com\/wp-content\/uploads\/2015\/09\/RES.gif\" title='RES' alt='' \/><\/div><\/a><\/div><\/div><\/div>\n<div class='flex_column av-8or342-e3cdb0d34e9504c70be7d2ce0c8e33be av_one_half  avia-builder-el-2  el_after_av_one_half  el_before_av_one_fourth  flex_column_div '     ><section  class='av_textblock_section av-72i902-74ff831cae6cebd7285d8fcd69c569be'  itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><h1><span style=\"color: #488113;\"><strong>Module Interne de Mesure de R\u00e9sistance &#8211; RES-24<\/strong><\/span><\/h1>\n<p><span style=\"color: #488113;\"><strong style=\"color: #333333; font-size: 14px; line-height: 1.5em;\"><span style=\"color: #000000; font-size: 18px;\">R\u00e9f : RES-24<\/span><\/strong><\/span><\/p>\n<\/div><\/section><br \/>\n<section  class='av_textblock_section av-5cids2-512f82b8a93ef2af4a1ee9756f4fe28d'  itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><div style=\"text-align: justify;\">\n<p>Le module <strong>RES-24<\/strong> est con\u00e7u pour mesurer la <strong>r\u00e9sistance d\u2019insertion des contacts auxiliaires r\u00e9sistifs<\/strong> lors des man\u0153uvres d\u2019ouverture et de fermeture des disjoncteurs r\u00e9alis\u00e9es avec le syst\u00e8me <strong>CBA-32P<\/strong>.<\/p>\n<p>Lors des essais de chronom\u00e9trage standards des disjoncteurs r\u00e9alis\u00e9s avec le <strong>CBA-32P<\/strong> et analys\u00e9s \u00e0 l\u2019aide du logiciel <strong>CBA Win\u00a9<\/strong>, les \u00e9tats des contacts auxiliaires sont repr\u00e9sent\u00e9s sous forme de signaux logiques : <strong>ouvert (0), ferm\u00e9 (1) et transition r\u00e9sistive (0,5)<\/strong>. Cette repr\u00e9sentation permet d\u2019identifier clairement l\u2019\u00e9tat des contacts pendant la man\u0153uvre, mais ne fournit pas la <strong>valeur r\u00e9elle de leur r\u00e9sistance \u00e9lectrique en ohms<\/strong>, que ce soit pendant la transition ou dans les \u00e9tats stabilis\u00e9s.<\/p>\n<p>Le <strong>module interne de mesure de r\u00e9sistance RES-24<\/strong> permet d\u2019obtenir cette information compl\u00e9mentaire en mesurant la <strong>r\u00e9sistance d\u2019insertion r\u00e9elle des contacts auxiliaires<\/strong> pendant les man\u0153uvres d\u2019ouverture et de fermeture. Au lieu de fournir uniquement une indication logique de l\u2019\u00e9tat des contacts, le syst\u00e8me fournit des <strong>valeurs de r\u00e9sistance en ohms en temps r\u00e9el<\/strong> pendant les \u00e9v\u00e9nements de commutation.<\/p>\n<p>Ces mesures sont r\u00e9alis\u00e9es pendant la <strong>man\u0153uvre dynamique du disjoncteur<\/strong> et sont enti\u00e8rement synchronis\u00e9es avec l\u2019acquisition du chronom\u00e9trage effectu\u00e9e par le syst\u00e8me <strong>CBA-32P<\/strong>. Chaque valeur de r\u00e9sistance peut ainsi \u00eatre directement corr\u00e9l\u00e9e \u00e0 l\u2019instant pr\u00e9cis de la man\u0153uvre m\u00e9canique et \u00e9lectrique du disjoncteur.<\/p>\n<p>Les valeurs de r\u00e9sistance mesur\u00e9es sont ensuite int\u00e9gr\u00e9es dans l\u2019environnement logiciel <strong>CBA Win\u00a9<\/strong>, o\u00f9 elles sont affich\u00e9es conjointement avec les <strong>courbes de chronom\u00e9trage<\/strong> et les <strong>traces d\u2019\u00e9tat des contacts auxiliaires<\/strong>, dans des rapports graphiques et tabulaires. Les op\u00e9rateurs peuvent ainsi analyser le comportement du disjoncteur lors de ses man\u0153uvres ainsi que l\u2019\u00e9tat des contacts au sein d\u2019un <strong>ensemble de donn\u00e9es unique<\/strong>.<\/p>\n<\/div>\n<\/div><\/section><br \/>\n<section  class='av_textblock_section av-muzmbl4n-c8169e857c19d390454d95acf811de41'  itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><h2>PRINCIPAUX AVANTAGES<\/h2>\n<div style=\"text-align: justify;\">\n<ul>\n<li>Mesure en temps r\u00e9el de la <strong>r\u00e9sistance d\u2019insertion des contacts auxiliaires<\/strong> lors des man\u0153uvres d\u2019ouverture et de fermeture du disjoncteur<\/li>\n<li>Compl\u00e8te la repr\u00e9sentation logique standard de CBA Win\u00a9 <strong>(0 \/ 1 \/ 0,5)<\/strong> par les valeurs r\u00e9elles de r\u00e9sistance en ohms<\/li>\n<li>Permet une <strong>\u00e9valuation quantitative de l\u2019\u00e9tat \u00e9lectrique des contacts auxiliaires<\/strong>, au-del\u00e0 de la simple indication de leur \u00e9tat<\/li>\n<li>Enti\u00e8rement synchronis\u00e9 avec l\u2019acquisition du chronom\u00e9trage du <strong>CBA-32P<\/strong> pour une corr\u00e9lation pr\u00e9cise avec les \u00e9v\u00e9nements de commutation<\/li>\n<li>Permet de d\u00e9tecter les <strong>r\u00e9sistances de contact anormales, les ph\u00e9nom\u00e8nes de d\u00e9gradation et les comportements de commutation irr\u00e9guliers<\/strong><\/li>\n<li>Int\u00e9gr\u00e9 aux rapports <strong>graphiques et tabulaires de CBA Win\u00a9<\/strong> pour une analyse combin\u00e9e des donn\u00e9es de r\u00e9sistance et de chronom\u00e9trage<\/li>\n<\/ul>\n<\/div>\n<\/div><\/section><\/p><\/div><div class='flex_column av-3t8poy-ec18f2d639b868c04221b0d2a40d5479 av_one_fourth  avia-builder-el-6  el_after_av_one_half  avia-builder-el-last  first flex_column_div column-top-margin'     ><section  class='av_textblock_section av-2ovyb6-bb0a7cd122bc0f288ff8f2a170b59ebc'  itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><p><strong><span style=\"color: #488113;\">BROCHURE<\/span><\/strong><\/p>\n<p><a href=\"https:\/\/www.zensol.com\/wp-content\/uploads\/2016\/11\/RES-81624.pdf\" rel=\"attachment wp-att-5553\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-5553\" src=\"https:\/\/www.zensol.com\/wp-content\/uploads\/2016\/11\/icone-pdf2.jpg\" alt=\"icone-pdf2\" width=\"138\" height=\"110\" \/><\/a><\/p>\n<\/div><\/section><\/div><\/p>\n","protected":false},"excerpt":{"rendered":"","protected":false},"featured_media":3906,"comment_status":"open","ping_status":"open","template":"","tags":[],"portfolio_entries":[102,200,105],"class_list":["post-3938","portfolio","type-portfolio","status-publish","has-post-thumbnail","hentry","portfolio_entries-accessoires","portfolio_entries-circuit-breaker-accessoires-2-fr","portfolio_entries-principaux-accessoires"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Module Interne de Mesure de R\u00e9sistance - RES<\/title>\n<meta name=\"description\" content=\"Le module interne RES a \u00e9t\u00e9 con\u00e7u pour la mesure de la r\u00e9sistance d&#039;insertion des temps d&#039;ouverture et de fermeture des contacts auxiliaires de disjoncteurs.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.zensol.com\/fr\/product\/res-24\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Module Interne de Mesure de R\u00e9sistance - RES\" \/>\n<meta property=\"og:description\" content=\"Le module interne RES a \u00e9t\u00e9 con\u00e7u pour la mesure de la r\u00e9sistance d&#039;insertion des temps d&#039;ouverture et de fermeture des contacts auxiliaires de disjoncteurs.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.zensol.com\/fr\/product\/res-24\/\" \/>\n<meta property=\"og:site_name\" content=\"Zensol\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-12T07:24:49+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.zensol.com\/wp-content\/uploads\/2015\/09\/RES.gif\" \/>\n\t<meta property=\"og:image:width\" content=\"388\" \/>\n\t<meta property=\"og:image:height\" content=\"295\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/gif\" \/>\n<meta name=\"twitter:label1\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.zensol.com\\\/fr\\\/product\\\/res-24\\\/\",\"url\":\"https:\\\/\\\/www.zensol.com\\\/fr\\\/product\\\/res-24\\\/\",\"name\":\"Module Interne de Mesure de R\u00e9sistance - RES\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.zensol.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.zensol.com\\\/fr\\\/product\\\/res-24\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.zensol.com\\\/fr\\\/product\\\/res-24\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.zensol.com\\\/wp-content\\\/uploads\\\/2015\\\/09\\\/RES.gif\",\"datePublished\":\"2015-12-21T17:10:44+00:00\",\"dateModified\":\"2026-10-12T07:24:49+00:00\",\"description\":\"Le module interne RES a \u00e9t\u00e9 con\u00e7u pour la mesure de la r\u00e9sistance d'insertion des temps d'ouverture et de fermeture des contacts auxiliaires de disjoncteurs.\",\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.zensol.com\\\/fr\\\/product\\\/res-24\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/www.zensol.com\\\/fr\\\/product\\\/res-24\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.zensol.com\\\/wp-content\\\/uploads\\\/2015\\\/09\\\/RES.gif\",\"contentUrl\":\"https:\\\/\\\/www.zensol.com\\\/wp-content\\\/uploads\\\/2015\\\/09\\\/RES.gif\",\"width\":388,\"height\":295},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.zensol.com\\\/#website\",\"url\":\"https:\\\/\\\/www.zensol.com\\\/\",\"name\":\"Zensol\",\"description\":\"The Circuit Breaker, Recloser and Tap-Changer Instrument Test Specialist\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.zensol.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Module Interne de Mesure de R\u00e9sistance - RES","description":"Le module interne RES a \u00e9t\u00e9 con\u00e7u pour la mesure de la r\u00e9sistance d'insertion des temps d'ouverture et de fermeture des contacts auxiliaires de disjoncteurs.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.zensol.com\/fr\/product\/res-24\/","og_locale":"fr_FR","og_type":"article","og_title":"Module Interne de Mesure de R\u00e9sistance - RES","og_description":"Le module interne RES a \u00e9t\u00e9 con\u00e7u pour la mesure de la r\u00e9sistance d'insertion des temps d'ouverture et de fermeture des contacts auxiliaires de disjoncteurs.","og_url":"https:\/\/www.zensol.com\/fr\/product\/res-24\/","og_site_name":"Zensol","article_modified_time":"2026-10-12T07:24:49+00:00","og_image":[{"width":388,"height":295,"url":"https:\/\/www.zensol.com\/wp-content\/uploads\/2015\/09\/RES.gif","type":"image\/gif"}],"twitter_misc":{"Dur\u00e9e de lecture estim\u00e9e":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.zensol.com\/fr\/product\/res-24\/","url":"https:\/\/www.zensol.com\/fr\/product\/res-24\/","name":"Module Interne de Mesure de R\u00e9sistance - RES","isPartOf":{"@id":"https:\/\/www.zensol.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.zensol.com\/fr\/product\/res-24\/#primaryimage"},"image":{"@id":"https:\/\/www.zensol.com\/fr\/product\/res-24\/#primaryimage"},"thumbnailUrl":"https:\/\/www.zensol.com\/wp-content\/uploads\/2015\/09\/RES.gif","datePublished":"2015-12-21T17:10:44+00:00","dateModified":"2026-10-12T07:24:49+00:00","description":"Le module interne RES a \u00e9t\u00e9 con\u00e7u pour la mesure de la r\u00e9sistance d'insertion des temps d'ouverture et de fermeture des contacts auxiliaires de disjoncteurs.","inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.zensol.com\/fr\/product\/res-24\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.zensol.com\/fr\/product\/res-24\/#primaryimage","url":"https:\/\/www.zensol.com\/wp-content\/uploads\/2015\/09\/RES.gif","contentUrl":"https:\/\/www.zensol.com\/wp-content\/uploads\/2015\/09\/RES.gif","width":388,"height":295},{"@type":"WebSite","@id":"https:\/\/www.zensol.com\/#website","url":"https:\/\/www.zensol.com\/","name":"Zensol","description":"The Circuit Breaker, Recloser and Tap-Changer Instrument Test Specialist","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.zensol.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"}]}},"_links":{"self":[{"href":"https:\/\/www.zensol.com\/fr\/wp-json\/wp\/v2\/portfolio\/3938","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.zensol.com\/fr\/wp-json\/wp\/v2\/portfolio"}],"about":[{"href":"https:\/\/www.zensol.com\/fr\/wp-json\/wp\/v2\/types\/portfolio"}],"replies":[{"embeddable":true,"href":"https:\/\/www.zensol.com\/fr\/wp-json\/wp\/v2\/comments?post=3938"}],"version-history":[{"count":8,"href":"https:\/\/www.zensol.com\/fr\/wp-json\/wp\/v2\/portfolio\/3938\/revisions"}],"predecessor-version":[{"id":15304,"href":"https:\/\/www.zensol.com\/fr\/wp-json\/wp\/v2\/portfolio\/3938\/revisions\/15304"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.zensol.com\/fr\/wp-json\/wp\/v2\/media\/3906"}],"wp:attachment":[{"href":"https:\/\/www.zensol.com\/fr\/wp-json\/wp\/v2\/media?parent=3938"}],"wp:term":[{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.zensol.com\/fr\/wp-json\/wp\/v2\/tags?post=3938"},{"taxonomy":"portfolio_entries","embeddable":true,"href":"https:\/\/www.zensol.com\/fr\/wp-json\/wp\/v2\/portfolio_entries?post=3938"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}