MODEL NUMBER ORDERING EXPLANATION FOR CBA-32 ANALYZERS
| CBA-32P-8C-5A-S-800kV | |
|
Model |
CBA-32P |
| Number of contact inputs 8C - eight contact inputs 16C - sixteen contact inputs 24C - twenty-four contact inputs |
CBA-32P-8C |
| Number of analog inputs (displacement, pressure, etc.) | |
| 2A - 2 built-in analog current sensors | CBA-32P-8C-5A |
| 5A - five analog inputs (0-10 VDC) including 2 built-in current sensors and 3 general purpose analog inputs. For linear displacement or general purpose, power is supplied by the CBA-32. 8A - eight analog inputs (0-10 VDC) including 2 built-in current sensors and 6 general purpose analog inputs. For linear displacement or general purpose, power is supplied by the CBA-32.. |
|
| Size | CBA-32P-8C-5A-S |
| S small version (H 16.5" X L 10" X W 14.5" o H 41.9cm X L 25.4cm X W 36.8cm) 12.5 kg/27.5 lb L large version (H 21" X L 11" X W 18.5" o H 53.3cm X L 27.9cm X W 47cm) 14.5 kg/31.9 lb D desktop - Standard 19" mounted rack |
|
| Environment (does not apply to Desktop models) 400kV unit can be used in noisy 400kV environment 800kV unit can be used in very noisy 800 kV environment |
CBA-32P-8C-5A-S-800kV |
| Number of control outputs included 2 breaker control outputs able to switch AC and DC coil command signals. Coil current is measured by two built-in analog inputs which are standard with every CBA-32 unit. Included with a CBA-32 of either model is the following equipment: - CBA WIN™ - 10 feet fiber optic cable (Ref: FIB-10) - Adapter for RS232/fiber optic data link, power supply included (Ref: KIT-ZB1-E) - Complete set of I/O cables (Ref: KIT-CON-10) - Complete set of manuals (Ref: KIT-MAN) - Training at Zensol premises (travel expenses of the attendees not included) Main Voltages 120V/60Hz OR 220V/50Hz (please specify when ordering) If custom specifications are required, please contact the manufacturer directly. |
|